iLivTouch®Non-invasive Liver Disease Management System
The iLivTouch® series is Hisky Medical’s non-invasive liver disease management solution, integrating advanced Vibration-Controlled Transient Elastography (VCTE/TE) and ultrasound imaging technologies. By providing quantitative liver stiffness measurement (LSM) and ultrasound attenuation assessment(UAP), iLivTouch® systems support liver fibrosis staging, steatosis evaluation, and treatment monitoring across multiple clinical settings.

Non-invasive

Quantitative

Rapid

Accurate

UAP
Ultrasound Attenuation Parameter, dB/m
Assessment of Liver Steatosis
LSM
Liver Stiffness Measurement, kPa
Assessment of liver Fibrosis
LivQ-box LIID*
Liver disease Quantitative-box Liver Inflammatory InDex
Assessment of MASH
SSM*
Spleen Stiffness Measurement
Assists in portal hypertension evaluation, significantly improves the endoscopy exemption rate
SUP*
Splenic Ultrasound Parameters
Assists in portal hypertension evaluation, significantly improves the endoscopy exemption rate
Parameters marked with an asterisk are for research use only.
Clinical Applications

The iLivTouch® system supports a wide range of clinical applications, including:

  - Chronic hepatitis B and C management 

  - Metabolic dysfunction-associated steatotic liver disease (MASLD)/MAFLD assessment 

  - Liver steatosis monitoring 

  - Liver fibrosis and cirrhosis evaluation 

  - Treatment response assessment and follow-up


The Technical Advantages of iLivTouch®
Ultrasound guidance
Scientific and intuitive locating method
Wideband frequency probe
Applicable to patients of different body sizes
TE + Ultrasound Diagnosis
Multi-functional device
Multi-mode fusion probe
Integrating ultrasound imaging and elasticity measurement
Multichannel tissue information scanning
The detection sample volume is 30cm³, which is 1000 times larger than liver biopsy sample volume
This technology is available in some models. For details, please refer to the specific product models.
Voice of Authority

iLivTouch® Series
Mini Series
FT Series
Pro Series
Plus Series
Max Series
Mini Series
Applied Technology
Vibration-Controlled Transient Elastography (TE)
Examination Method
Probe touch detection
Data Processing
Optimized scientific algorithms
Convex Probe
-
Fibrosis Scanning Probe
Dynamic wideband frequency, real-time transmitting and receiving ultrasonic waves,controlled low-frequency shear wave
Function

• Liver Stiffness Measurement (LSM)
• Ultrasound Attenuation Parameter (UAP)
Other Product Information

• 7kg of weight. easy to carry around
• 3 hours of battery life for remote use
• Fully featured with the ability to test LSM and UAP
• Compatible with add-on ultrasound probe*
• CE & US FDA: FT100, Mini800
FT Series
Applied Technology
Vibration-Controlled Transient Elastography (TE), 2D imaging technology
Examination Method
Probe touch detection
Data Processing
Optimized scientific algorithms
Convex Probe
Scanning depth >200mm, real-time transmitting and receivingultrasonic wave
Fibrosis Scanning Probe
Dynamic wideband frequency, real-time transmitting and receiving ultrasonic waves,controlled low-frequency shear wave
Function

• Liver Stiffness Measurement (LSM)
• Ultrasound Attenuation Parameter (UAP)
• Assessment of liver tissue morphology by 2D ultrasound
Other Product Information

• Image-guided Ultrasound for accurate positioning
• 19”high-resolution LCD to better visualize the testing process
• Integrated design brings stable performance
• FT1000: CE
• FT9000: CE, US FDA
Pro Series
Applied Technology
Vibration-Controlled Transient Elastography (TE), 2D imaging technology
Examination Method
Probe touch detection
Data Processing
Optimized scientific algorithms
Convex Probe
Scanning depth >200mm, real-time transmitting and receivingultrasonic wave
Fibrosis Scanning Probe
Dynamic wideband frequency, real-time transmitting and receiving ultrasonic waves,controlled low-frequency shear wave
Function

• Liver Stiffness Measurement (LSM)
• Ultrasound Attenuation Parameter (UAP)
• Assessment of liver tissue morphology by 2D ultrasound
Other Product Information

• Image-guided Ultrasound for accurate positioning
• 21.5”high-resolution LCD to better visualize the testing process
• Integrated design brings stable performance
• Pro9000: CE
Plus Series
Applied Technology
Vibration-Controlled Transient Elastography (TE), 2D imaging technology
Examination Method
Probe touch detection
Data Processing
Optimized scientific algorithms
Convex Probe
Scanning depth >190mm, real-time transmitting and receiving ultrasonic wave
Fibrosis Scanning Probe
Dynamic wideband frequency, real-time transmitting and receiving ultrasonic waves,controlled low-frequency shear wave
Function

• Liver Stiffness Measurement(LSM)
• Ultrasound Attenuation Parameter (UAP)
• Assessment of liver tissue morphology by 2D ultrasound
Other Product Information

• Color Doppler system available for color ultrasound application in abdomen
• Simultaneous determination of LSM and UAP
• Build-in touchscreen for easy operation
• Plus9000: CE
Max Series
Applied Technology
MigTE(Multichannel image guided Transient Elastography), Color DopplerUltrasound Guidance
Examination Method
Probe touch detection
Data Processing
Optimized scientific algorithms
Convex Probe
Multi-mode Fusion Probe, wideband frequency
Fibrosis Scanning Probe
Support ultrasound examination of abdomen, e.g. liver, pancreas, spleen,kidney, etc.
Function

• Liver Stiffness Measurement(LSM)
• Ultrasound Attenuation Parameter (UAP)
• Color Doppler Ultrasound Guidance
Other Product Information

• One Multi-Mode Fusion Probe does ultrasound imaging and measurement of liver stiffness and UAP
• Multichannel and large-scale tissue information reconstruction,detection sample volume is 30cm3
• Dual display of multiple results on one screen
• High-end color doppler ultrasound assists in diagnosis
• FH9000: CE
Learn more about product tech Learn about related clinical research
If you need more product information, please contact us.